Key Conclusions:It is common for servo drives to exhibit high-frequency leakage current flowing through EMI filter capacitors to protective ground, which is a normal occurrence; however, a live chassis or frequent tripping of the ground fault circuit interrupter (GFCI) constitutes a malfunction and should be troubleshot by following a four-step process covering the power supply, grounding, cabling, and motor.
Basis for Identifying State Changes
First, check whether the protective grounding connection is secure. Excessive grounding resistance is the most common cause of a live chassis and is also the most easily overlooked.
The higher the carrier frequency of the servo drive and the longer the motor cable, the greater the distributed capacitance to ground, and the higher the leakage current.
Routine Inspections and Preventive Maintenance
- Standard ground-fault circuit interrupters (GFCIs) are prone to false trips; in industrial settings, it is advisable to select models that are insensitive to high-frequency components or to adjust the settings according to the manufacturer’s recommendations.
- Damage to the insulation of motor power cables or moisture in the connections can cause a decrease in actual insulation resistance; therefore, it is necessary to measure each section with a megohmmeter rather than relying solely on error codes.
- Do not disconnect the protective grounding to prevent a trip; doing so compromises both EMC and personal safety.
Common Alarms and Troubleshooting Steps
| Phenomenon | Prioritize Investigation |
|---|---|
| Significant positional error | Mechanical jamming, acceleration/deceleration parameters, encoder feedback, workpiece interference exceeding limits |
| Busbar Overvoltage | Deceleration Time, Load Inertia, Braking Resistor Power, and Resistance |
| Curve Jitter | Power and signal lines run together; shielding grounded at both ends; ground loop current |
| Accuracy Drift | Temperature rise in the lead screw, lubrication degradation, loose fixtures, sensor zero point |
Related Equipment and Further Reading
Apply the above parameters to a specific device to verify them. We recommend referring to the following as well:Servo Press Motor Rotor Press-Fit Machine、Positioning Pins and Steel Ball Press-Fit Equipment、High-Speed Chain Automated Assembly Line。
For systematic principles and selection methods, see The Complete Guide to Servo Presses; For a complete list of models and specifications, see Product Center。
Frequently Asked Questions
Is a slight tingling sensation on the case a sign of normal leakage current?
No. Normal high-frequency leakage current should not cause a perceptible electric shock; you must check the grounding and insulation.
If a ground fault circuit interrupter trips, can it be replaced directly with one rated for a higher current?
No, you must first locate the source of the ground fault; otherwise, you’ll mask the insulation failure.
If you need to calculate thrust, stroke, or the determination window based on your workpiece, or if you would like to request technical documentation, please visitDownload Product Brochures、prescription, or directly through Contact Us Submit your operating conditions, and engineers from Shanghai WINTRL Automation will provide product selection recommendations. For company background, seeAbout Us。